Corrosion Resistant Long-Lasting Electrolytic Cell Long Service Life FRP GRP Electrolyzer

Product Details
Customization: Available
After-sales Service: Installation, Commissioning and Training
Warranty: 3 Years

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 30 days
Quality Assurance
The supplier provides quality assurance
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (16)
  • Corrosion Resistant Long-Lasting Electrolytic Cell Long Service Life FRP GRP Electrolyzer
  • Corrosion Resistant Long-Lasting Electrolytic Cell Long Service Life FRP GRP Electrolyzer
  • Corrosion Resistant Long-Lasting Electrolytic Cell Long Service Life FRP GRP Electrolyzer
  • Corrosion Resistant Long-Lasting Electrolytic Cell Long Service Life FRP GRP Electrolyzer
  • Corrosion Resistant Long-Lasting Electrolytic Cell Long Service Life FRP GRP Electrolyzer
  • Corrosion Resistant Long-Lasting Electrolytic Cell Long Service Life FRP GRP Electrolyzer
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Structure
  • Advantage
  • Application
  • Packaging & Shipping
  • Company Profile
Overview

Basic Info.

Model NO.
Customized
Customized
Customized
Condition
New
Power Source
Electric
Automatic Grade
Automatic
Certification
ISO, CE
Name
FRP Electrolytic Cell
Application
Metal Purification and Extraction
Non-Ferrous Metals
Copper, Zinc, Nickel, Cobalt, Lead, Gold, etc.
Usage
Electrowinning or Electrorefining
Medium
Hot Electrolyte
Industry
Non-Ferrous Metal Refining
Advantage
Long Service Life, Safe, High Purity Productivity
Features
Corrosion Resistance, Impermeability
Certifications
ISO, CE
Transport Package
Steel Frame, Wood Saddle
Specification
Customized
Trademark
ALD
Origin
China
HS Code
8543300090
Production Capacity
8000 Pieces/Month

Product Description

Product Description

Corrosion Resistant Long-Lasting Electrolytic Cell Long Service Life FRP GRP Electrolyzer
1.Vinyl ester resin monolithic casting electrolytic cells
       Electrolytic cells are designed, built and installed to satisfy the most stringent requirements requested by tankhouse operators worldwide. In most cases their main request is to guarantee full operating availability throughout the plant's lifespan, maximizing production of high-purity metal (copper, zinc, nickel, cobalt, lead gold or other non-ferrous metals) with absolute safety for people and the environment. Additionally, cells must accommodate changes for continuous improvement of the electrolytic process, integrating efficiently with upgrades of complementary equipment such as anodes, cathodes, cap, boards, overhead crane electrolyte agitation systems, acid mist control devices, thermal insulation among many others.

Specification


List of Existing Mold(Large quantity can be customized)
 
No. Dimension L*W*H (mm)
1 11000*1330*2360
2 5840*1170*1400/1600
3 4800*940*1650
4 7370*1180*1480
5 4362*940*1855
6 4640*990*1600
7 3850*960*1579
8 3400*960*1579
9 5200*890*1370/1550
10 6700*1200*1540
11 5000*1170*1500/1700
12 5200*1200*1480
13 6660*1220*1540
14 4150*840*1564
15 5970*1170*1400/1600
16 2900*1200*1509 
17 8370*1120*1730
18 5100*960*1600
19 4030*940*1650
20 4530*1010*1640
21 4970*1160*1400
22 2300*700*1600
23 4000*1420*1000
24 5000*1200*1400
25 5900*1200*1950
26 5000*820*1650
27 5840*1170*1400*1700
28 4180*990*1500/1615
29 5300*940*1650
30 5050*1070*1950
31 3470*870*1250

Structure

Corrosion Resistant Long-Lasting Electrolytic Cell Long Service Life FRP GRP ElectrolyzerElectrolytic cells are cast monolithically based on a patented, three-layer composite material system:
      1.The Internal layer is a monolithic tank made with multiple layers of fiber-reinforced vinyl ester resin (FRP) complying with chemical barrier international norms that assure long-term impermeability and corrosion resistance.

      2.The Intermediate layer is the structural core made with polymer Concrete, with a patented formulation to achieve a low coefficient of thermal expansion, providing long-term structural integrity with low thermally-induced stresses

      3.The External layer is a standard seal layer of FRP that further protects the structural core from electrolyte splashes and spills. Optionally, this external seal may be specified with multi-layered oriented fiber reinforcements to guarantee trouble-free operation in unusually extreme operating environments.

Advantage

Corrosion Resistant Long-Lasting Electrolytic Cell Long Service Life FRP GRP Electrolyzer1)Long-term impermeability, free of corrosion, 20+ years warranty
Our monolithic internal tank manufactured with multiple layers of fiber-reinforced premium vinyl ester resin. It has continuous service without leakage, free of corrosion and structural flaws which operating under normal conditions as specified for each project.

(2)Swift, accurate and less costly installation
Electrolytic cells include features that allow reduction of 25% or more in time needed for cell erection, alignment and leveling compared to time required with conventional polymer concrete cells. Dimension tolerances for electrolytic cells are consistently tight, simplifying installation in the most demanding applications, including plants with automated crane systems. 

(3)Minimum cleaning time and water consumption
The rounded internal shape, optional sloped cell floors, and smooth, flat finish of the internal tank, facilitate water sweeping and drainage of heavy sludge, with reduced water usage and accelerating return to service after each cleaning.

(4)Minimum maintenance cost
The robust, virtually impervious internal tank that is chemically bound to the polymer concrete structural core during molding is tolerant to operating abuse its smooth, non-stick surfaces minimize adhesion of contaminants.

(5)Maximum operational safety
The structural core of electrolytic cells is bolstered with sturdy external seismic reinforcement blocks confining its floor supports, and includes a robust, internal bidirectional, pultruded FRP bar mesh reinforcement which positively maintains integrity should the cell fail due to catastrophic events. Electrolytic cell installation protocols call for lateral wall collaboration between cells, thus reducing stress levels of cell around 40% under normal operating conditions.

Application

Corrosion Resistant Long-Lasting Electrolytic Cell Long Service Life FRP GRP ElectrolyzerCorrosion Resistant Long-Lasting Electrolytic Cell Long Service Life FRP GRP Electrolyzer

Packaging & Shipping

Corrosion Resistant Long-Lasting Electrolytic Cell Long Service Life FRP GRP Electrolyzer

Company Profile

Corrosion Resistant Long-Lasting Electrolytic Cell Long Service Life FRP GRP ElectrolyzerCorrosion Resistant Long-Lasting Electrolytic Cell Long Service Life FRP GRP ElectrolyzerCorrosion Resistant Long-Lasting Electrolytic Cell Long Service Life FRP GRP ElectrolyzerCorrosion Resistant Long-Lasting Electrolytic Cell Long Service Life FRP GRP ElectrolyzerDo you offer customization?
Sure, we are a manufacturer with more than 16 years of production experience, with experienced technicians and workers to fully meet the customization needs of customers.

Are you a factory or a trading company?
We are a factory, is a professional manufacturer, we have more than 200 skilled technicians, in addition, we have professional equipment mold engineers for design and production.

Where is your factory located? How can I visit you?
Our sales office is located in Shijiazhuang, Hebei Province. And our factory in Hengshui, Hebei Province.

Can you do OEM?
Yes, we can do OEM and ODM products, no problem. We can make all kinds of customized products according to drawings or samples.

Can you provide technical advice?
We provide you with professional technical advice free of charge.

What volume do you have?
With an annual output of 60,000 tons, we have multiple production lines to meet customer requirements for fast delivery.

What are your payment methods?
We accept TT /LC/Credit insurance orders.

What are your delivery items?
We accept EXW,FOB,CNF,CIF, etc. You can choose the one that is most convenient and cheapest.

What's the price of GRP FRP Electrolytic Cell?
Please contact us, we will give you a reliable quotation.

How much is the GRP FRP Electrolytic Cell?
Please contact us, we will give you a reliable quotation.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier